BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//PSD - ECPv6.15.11//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://psdconsulting.com
X-WR-CALDESC:Events for PSD
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20240310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20241103T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20250309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20251102T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20250507T083000
DTEND;TZID=America/New_York:20250507T100000
DTSTAMP:20260414T163140
CREATED:20250424T193504Z
LAST-MODIFIED:20250424T194322Z
UID:22723-1746606600-1746612000@psdconsulting.com
SUMMARY:Residential Air Sealing to 3 ACH50 - PART 1
DESCRIPTION:Relevant market research\, including the DOE Residential Field Study\, revealed significant noncompliance with 3 ACH50\, and multiple other field studies in nearby geographies and uncovered lack of proper insulation installation. This webinar training covers air sealing\, air barriers\, blower-door testing\, identification of potential leakage sites in CAD details\, 3D graphics\, and photographs\, for single family residential including other issues\, such as party walls\, in low-rise multifamily. This webinar is Part 1 of a two-part series on energy code envelope requirements. Both webinars include test-your-knowledge questions\, and guided discussion of pros/cons of various strategies. \nLearning Objectives: \n1. Understand how to review\, install\, and inspect details necessary to achieve an envelope leakage rate of 3 ACH50 or less \n2. Differentiate between several air sealing techniques \n3. Identify and resolve common leakage areas \n4. Understand code requirements for air sealing from the 2020 ECCCNYS Table 402.4.1.1 Air Barrier and Insulation Installation.
URL:https://psdconsulting.com/calendar/residential-air-sealing-to-3-ach50-part-1/
CATEGORIES:New York Energy Code Training,Residential
ATTACH;FMTTYPE=image/png:https://psdconsulting.com/wp-content/uploads/2023/01/new-york.png
END:VEVENT
END:VCALENDAR