BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//PSD - ECPv6.15.11//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:PSD
X-ORIGINAL-URL:https://psdconsulting.com
X-WR-CALDESC:Events for PSD
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20240310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20241103T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20250309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20251102T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251125T123000
DTEND;TZID=America/New_York:20251125T140000
DTSTAMP:20260403T141620
CREATED:20251003T173256Z
LAST-MODIFIED:20251003T173256Z
UID:23023-1764073800-1764079200@psdconsulting.com
SUMMARY:C6.1 - Foam without Flames – Part 1 – Thermal Bridging
DESCRIPTION:C6.1 – Foam without Flames – Part 1 – Thermal Bridging \nT02-07-3230 \nCOURSE DESCRIPTION Reducing thermal bridging is one of the keys to reducing energy waste in buildings and\, to that end\, the prescriptive energy code contains requirements for continuous insulation for roofs\, above-and below-grade walls\, and mass floors. This program will provide an overview of the thermal envelope requirements in the ECCCNYS [CE] and NYStretch [CE] as they relate to continuous insulation. This will be followed by a discussion the types of construction as categorized by the Building Code of New York State (Types I\, II\, III\, IV\, V) and associated fire-resistance rating requirements and fire separation distance requirements\, and NFPA 285 test for vertical and lateral flame spread as they relate to exterior foam applications.
URL:https://psdconsulting.com/calendar/c6-1-foam-without-flames-part-1-thermal-bridging-3/
CATEGORIES:Commercial,Commercial,New York Energy Code Training
ATTACH;FMTTYPE=image/png:https://psdconsulting.com/wp-content/uploads/2023/01/new-york.png
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251125T141500
DTEND;TZID=America/New_York:20251125T154500
DTSTAMP:20260403T141620
CREATED:20251003T173626Z
LAST-MODIFIED:20251003T173626Z
UID:23025-1764080100-1764085500@psdconsulting.com
SUMMARY:C6.2 - Foam without Flames – Part 2 – Fire Rated Assemblies
DESCRIPTION:C6.2 – Foam without Flames – Part 2 – Fire Rated Assemblies \nT02-07-3237 \nCOURSE DESCRIPTION: Reducing thermal bridging is one of the keys to reducing energy waste in buildings and\, to that end\, the prescriptive energy code contains requirements for continuous insulation for roofs\, above-and below-grade walls\, and mass floors. This program will provide an overview of the thermal envelope requirements in the ECCCNYS [CE] and NYStretch [CE] as they relate to continuous insulation. This will be followed by a discussion the types of construction as categorized by the Building Code of New York State (Types I\, II\, III\, IV\, V) and associated fire-resistance rating requirements and fire separation distance requirements\, and NFPA 285 test for vertical and lateral flame spread as they relate to exterior foam applications.
URL:https://psdconsulting.com/calendar/c6-2-foam-without-flames-part-2-fire-rated-assemblies-3/
CATEGORIES:Commercial,Commercial,New York Energy Code Training
ATTACH;FMTTYPE=image/png:https://psdconsulting.com/wp-content/uploads/2023/01/new-york.png
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251209T123000
DTEND;TZID=America/New_York:20251209T140000
DTSTAMP:20260403T141620
CREATED:20251205T214928Z
LAST-MODIFIED:20251205T214928Z
UID:23116-1765283400-1765288800@psdconsulting.com
SUMMARY:(R5.1) The Energy Code and Existing Buildings (Residential) - Part 1
DESCRIPTION:Residential – The Energy Code and Existing Buildings – Part 1 \nT02-07-3138 \nCOURSE DESCRIPTION This course will provide a review of IECC Chapter 5 [RE] provisions with an emphasis on situations where work performed on existing buildings requires them to meet the energy code like new construction. This includes additions\, new thermal envelope assemblies built as part of an alteration\, window replacements\, new heating\, cooling and duct systems\, new service hot water systems\, new lighting where 50 percent or more of the luminaires are replaced\, changes from unconditioned to conditioned space\, and commercial spaces converted to dwelling units. The course will provide numerous examples and ask attendees to identify the energy code requirements for each scenario. \n 
URL:https://psdconsulting.com/calendar/r5-1-the-energy-code-and-existing-buildings-residential-part-1-13/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251209T141500
DTEND;TZID=America/New_York:20251209T154500
DTSTAMP:20260403T141620
CREATED:20251205T215140Z
LAST-MODIFIED:20251205T215140Z
UID:23118-1765289700-1765295100@psdconsulting.com
SUMMARY:(R5.2) The Energy Code and Existing Buildings (Residential) - Part 2
DESCRIPTION:Residential – The Energy Code and Existing Buildings – Part 2 \nT02-07-3139 \nCOURSE DESCRIPTION This course will provide a review of IECC Chapter 5 [RE] provisions with an emphasison situations where work performed on existing buildings requires them to meet the energy code like new construction. This includes additions\, new thermal envelope assemblies built as part of an alteration\, window replacements\, new heating\,cooling and duct systems\, new service hot water systems\, new lighting where 50 percent or more of the luminaires are replaced\, changes from unconditioned to conditioned space\, and commercial spaces converted to dwelling units. The course will provide numerous examples and ask attendees to identify the energy code requirements for each scenario.
URL:https://psdconsulting.com/calendar/r5-2-the-energy-code-and-existing-buildings-residential-part-2-13/
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251210T083000
DTEND;TZID=America/New_York:20251210T100000
DTSTAMP:20260403T141620
CREATED:20251205T215518Z
LAST-MODIFIED:20251205T215518Z
UID:23120-1765355400-1765360800@psdconsulting.com
SUMMARY:(R6.1) Don't Be Left Exposed - Part 1: Meeting the Energy Code with the Safe Use of Foam Insulation
DESCRIPTION:R6.1 – Don’t Be Left Exposed – Part 1 – Meeting the Energy Code with the Safe Use of Foam Insulation \nT02-07-3158 \nCOURSE DESCRIPTION Rigid foam board and spray foam insulation are common material choices to help achieve energy code compliance\, but when installed improperly can create fire hazards. Foam products general must be covered from the interior with thermal or ignition barriers\, but sometimes may be left exposed via “specific approvals.” The challenge for homebuilders\, design professionals\, insulation contractors\, and code officials is knowing which requirements apply to which applications. This course will cover RCNYS requirements for common applications of foam insulation in residential construction\, including crawl space walls\, basement walls\, roofs\, attic hatches\, knee walls\, rim joists\, and exterior sheathing. These requirements will be presented in the context of meeting ECCCNYS requirements for these building components.
URL:https://psdconsulting.com/calendar/r6-1-dont-be-left-exposed-part-1-meeting-the-energy-code-with-the-safe-use-of-foam-insulation-7/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251210T101500
DTEND;TZID=America/New_York:20251210T114500
DTSTAMP:20260403T141620
CREATED:20251205T215743Z
LAST-MODIFIED:20251205T215743Z
UID:23122-1765361700-1765367100@psdconsulting.com
SUMMARY:(R6.2) Don't Be Left Exposed - Part 2: Meeting the Energy Code with the Safe Use of Foam Insulation
DESCRIPTION:R6.2 – Don’t Be Left Exposed – Part 2 – Meeting the Energy Code with the Safe Use of Foam Insulation \nT02-07-3170 \nCOURSE DESCRIPTION Rigid foam board and spray foam insulation are common material choices to help achieve energy code compliance\, but when installed improperly can create fire hazards. Foam products general must be covered from the interior with thermal or ignition barriers\, but sometimes may be left exposed via “specific approvals.” The challenge for homebuilders\, design professionals\, insulation contractors\, and code officials is knowing which requirements apply to which applications. This course will cover RCNYS requirements for common applications of foam insulation in residential construction\, including crawl space walls\, basement walls\, roofs\, attic hatches\, knee walls\, rim joists\, and exterior sheathing. These requirements will be presented in the context of meeting ECCCNYS requirements for these building components.
URL:https://psdconsulting.com/calendar/r6-2-dont-be-left-exposed-part-2-meeting-the-energy-code-with-the-safe-use-of-foam-insulation-7/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251216T123000
DTEND;TZID=America/New_York:20251216T140000
DTSTAMP:20260403T141620
CREATED:20251205T220320Z
LAST-MODIFIED:20251205T220622Z
UID:23124-1765888200-1765893600@psdconsulting.com
SUMMARY:(S3.1) NYStretch Energy Code for Commercial Buildings (Pt 1)
DESCRIPTION:S3.1 NYStretch Energy Code for Commercial Buildings (Pt 1) 90 minutes \nT02-07-2987 \nCOURSE DESCRIPTION This course is Part 1 of a two-part series covering several requirements in the NYStretch Code for commercial buildings including: code compliance paths; building thermal envelope; mechanical systems; service water heating; commissioning; and\, additions and alterations. We also discuss the intention and benefits of this voluntary code and its relationship to the New York City energy code.
URL:https://psdconsulting.com/calendar/s3-1-nystretch-energy-code-for-commercial-buildings-pt-1-36/
CATEGORIES:New York Energy Code Training,Stretch Code
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251216T141500
DTEND;TZID=America/New_York:20251216T154500
DTSTAMP:20260403T141620
CREATED:20251205T220901Z
LAST-MODIFIED:20251205T220901Z
UID:23126-1765894500-1765899900@psdconsulting.com
SUMMARY:(S3.2) NYStretch Energy Code for Commercial Buildings (Pt 2)
DESCRIPTION:(S3.2) NYStretch Energy Code for Commercial Buildings (Pt 2) 90 minutes \nT02-07-2991 \nCOURSE DESCRIPTION This course is Part 2 of a two-part series covering several requirements in the NYStretch Code for commercial buildings including: Electric Power; Appendix CA; Kitchen Equipment and Elevators; Building Monitoring; Lighting; Total Building Performance; Additional Efficiency Packages and Appendix CC. We also discuss the intention and benefits of this voluntary code and its relationship to the New York City energy code. \n 
URL:https://psdconsulting.com/calendar/s3-2-nystretch-energy-code-for-commercial-buildings-pt-2-35/
CATEGORIES:New York Energy Code Training,Stretch Code
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251218T083000
DTEND;TZID=America/New_York:20251218T100000
DTSTAMP:20260403T141620
CREATED:20251205T221304Z
LAST-MODIFIED:20251205T221304Z
UID:23128-1766046600-1766052000@psdconsulting.com
SUMMARY:(C5.1) The Energy Code and Existing Buildings (Commercial) - Part 1
DESCRIPTION:C5.1 – The Energy Code and Existing Buildings (Commercial) – Part 1 \nT02-07-3163 \nCOURSE DESCRIPTION: This course will provide a review of IECC Chapter 5 [CE] provisions with an emphasis on situations where work performed on existing buildings requires them to meet the energy code like new construction. This includes additions\, new thermal envelope assemblies built as part of an alteration\, window replacements\, new heating\, cooling and duct systems\, new service hot water systems\, new lighting where 10 percent or more of the luminaires are replaced\, changes from unconditioned to conditioned space\, and commercial spaces converted to dwelling units. The course will provide numerous examples and ask attendees to identify the energy code requirements for each scenario \n 
URL:https://psdconsulting.com/calendar/c5-1-the-energy-code-and-existing-buildings-commercial-part-1-9/
CATEGORIES:Commercial,New York Energy Code Training
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251218T101500
DTEND;TZID=America/New_York:20251218T114500
DTSTAMP:20260403T141620
CREATED:20251205T221529Z
LAST-MODIFIED:20251205T221529Z
UID:23130-1766052900-1766058300@psdconsulting.com
SUMMARY:(C5.2) The Energy Code and Existing Buildings (Commercial) - Part 2
DESCRIPTION:C5.2 – The Energy Code and Existing Buildings (Commercial) – Part 2 \nT02-07-3164 \nCOURSE DESCRIPTION: This course will provide a review of IECC Chapter 5 [CE] provisions with an emphasis on situations where work performed on existing buildings requires them to meet the energy code like new construction. This includes additions\, new thermal envelope assemblies built as part of an alteration\, window replacements\, new heating\, cooling and duct systems\, new service hot water systems\, new lighting where 10 percent or more of the luminaires are replaced\, changes from unconditioned to conditioned space\, and commercial spaces converted to dwelling units. The course will provide numerous examples and ask attendees to identify the energy code requirements for each scenario.
URL:https://psdconsulting.com/calendar/c5-2-the-energy-code-and-existing-buildings-commercial-part-2-9/
CATEGORIES:Commercial,New York Energy Code Training
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251223T083000
DTEND;TZID=America/New_York:20251223T100000
DTSTAMP:20260403T141620
CREATED:20251205T221805Z
LAST-MODIFIED:20251205T221805Z
UID:23132-1766478600-1766484000@psdconsulting.com
SUMMARY:(R3.1) Residential Mechanical Systems: Whole House Ventilation (Pt 1)
DESCRIPTION:R3.1 Residential Mechanical Systems: Whole House Ventilation Part 1 \nT02-07-2857 \nCOURSE DESCRIPTION There has been a high interest in northeast states for education on the code requirements for whole-house mechanical ventilation. In this course attendees will understand the building science behind this important code requirement and be able define various methods of achieving compliance. In addition\, attendees will learn how to determine the minimum required ventilation rate based on house specifications and choose a system that meets the ventilation rates and fan efficacy requirements.
URL:https://psdconsulting.com/calendar/r3-1-residential-mechanical-systems-whole-house-ventilation-pt-1-21/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251223T101500
DTEND;TZID=America/New_York:20251223T114500
DTSTAMP:20260403T141620
CREATED:20251205T222130Z
LAST-MODIFIED:20251205T222130Z
UID:23134-1766484900-1766490300@psdconsulting.com
SUMMARY:(R3.2) Residential: Efficient Forced Air Distribution (Pt 2)
DESCRIPTION:R3.2 Residential: Efficient Forced Air Distribution Part 2 \nT02-07-2862 \nCOURSE DESCRIPTION In this course attendees will understand the importance of duct testing\, sealing\, and installation on the total performance of a house heating and cooling system. Attendees will be able to distinguish various code requirements based on duct proximity to the building thermal envelope. In addition\, attendees will learn duct insulation requirements and methods. Attendees will be introduced to a customizable Duct and Envelope Testing (DET) reporting form to make demonstrating code compliance straightforward and efficient.
URL:https://psdconsulting.com/calendar/r3-2-residential-efficient-forced-air-distribution-pt-2-26/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251230T123000
DTEND;TZID=America/New_York:20251230T140000
DTSTAMP:20260403T141620
CREATED:20251205T222341Z
LAST-MODIFIED:20251205T222341Z
UID:23136-1767097800-1767103200@psdconsulting.com
SUMMARY:(R7.1) Put a Lid On It Part 1: Unvented Attics
DESCRIPTION:R7.1 – Put a Lid On It Part 1 – Unvented Attics \nT02-07-3192 \nCOURSE DESCRIPTION Bringing attic and crawl spaces inside the thermal envelope is a great way to simultaneously improve energy efficiency and moisture management. One of the main ways unvented attics and crawl spaces reduce energy waste is by bringing ducts and air handlers inside (which is a requirement of NYStretch and the NYCECC). This can also be cost-effective for builders as they eliminate the requirement for duct testing. But there are risks associated with installing these assemblies improperly\, so it is important to meet all related requirements in the RCNYS. For unvented attics\, these include a minimum R-value of air impermeable insulation or above-roof deck insulation and proper installation and location of vapor retarders. For unvented crawl spaces\, builders must take care to install vapor barriers over exposed earth and provide a means of evacuating moisture. For both strategies\, the use of spray foam also brings in fire safety requirements from the RCNYS for thermal or ignition barriers. This course will provide a review of the benefits of unvented attics and crawl spaces\, related building science concepts\, and energy and residential code requirements.
URL:https://psdconsulting.com/calendar/r7-1-put-a-lid-on-it-part-1-unvented-attics-9/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20251230T141500
DTEND;TZID=America/New_York:20251230T154500
DTSTAMP:20260403T141620
CREATED:20251205T222559Z
LAST-MODIFIED:20251205T222559Z
UID:23138-1767104100-1767109500@psdconsulting.com
SUMMARY:(R7.2) Put a Lid On It Part 2: Unvented Crawlspaces
DESCRIPTION:R7.2 – Put a Lid On It Part 2 – Unvented Crawlspaces \nT02-07-3203 \nCOURSE DESCRIPTION Bringing attic and crawl spaces inside the thermal envelope isa great way to simultaneously improve energy efficiency and moisture management. One of the main ways unvented attics and crawl spaces reduce energy waste is by bringing ducts and air handlers inside (which is a requirement of NYStretch and the NYCECC). This can also be cost-effective for builders as they eliminate the requirement for duct testing. But there are risks associated with installing these assemblies improperly\, so it is important to meet all related requirements in the RCNYS. For unvented attics\, these include a minimum R-value of air impermeable insulation or above-roof deck insulation and proper installation and location of vapor retarders. For unvented crawl spaces\, builders must take care to install vapor barriers over exposed earth and provide a means of evacuating moisture. For both strategies\, the use of spray foam also brings in fire safety requirements from the RCNYS for thermal or ignition barriers.
URL:https://psdconsulting.com/calendar/r7-2-put-a-lid-on-it-part-2-unvented-crawlspaces-5/
CATEGORIES:New York Energy Code Training,Residential
END:VEVENT
END:VCALENDAR